The modular equipment structure and its universal connectivity offer the flexibility you need for a diverse range of measurement and control tasks, all with one instrument. Choose from a wide range of signal conditioners to optimally cover your measurement tasks. We will assist you in selecting the right type. Contact us.
Modules
Universal
UNI2-8 | UNI4 | |
---|---|---|
Channels | 8 | 4 |
TEDS | ||
Speed per Channel | ||
Max Sampling Rate | 100 kHz | 100 kHz |
Max Bandwidth | 48 kHz | 48 kHz |
Voltage Mode | ||
Isolated | ||
Voltage up to 10 V | ||
Voltage up to 50 V / 60 V | ||
Current | ||
20 mA Internal Shunt | ||
20 mA Shunt Plug | ||
Temperature | ||
Thermocouple (TC) | ||
PT100 | ||
Bridge Mode | ||
Full Bridge | ||
Half Bridge | ||
Quarter Bridge | ||
DC Excitation | ||
AC Excitation (CF) | ||
Audio and Vibration | ||
IEPE Mode Integrated (ICP-, DeltaTron-, PiezoTron) | ||
ICP Plug | ||
Charge | ||
Charge Mode Integrated | ||
Charge Plug | ||
Miscellaneous | ||
Sensor Supply | ||
Sensor Supply/Channel | ||
Slots required | 2 | 1 |
Voltage | Current | Temperature
LV-16 | LV3-8 | SC2-32 | OSC-16 | OSC-16-T | C-8 | C-8-T | ISO2-8 | ISO2-8-2T | ISOF-8 | HISO-8 | HV-4U | HV-2U2I | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Channels | 16 | 8 | 32 | 16 | 16 | 8 | 8 | 8 | 8 | 8 | 8 | 4 | 2+2 |
TEDS | 3 | ||||||||||||
Speed per Channel | |||||||||||||
Max Sampling Rate | 20 kHz | 100 kHz | 100 kHz | 5 Hz | 5 Hz | 20 kHz | 20 kHz | 100 kHz | 100 kHz | 100 kHz | 100 kHz | 100 kHz | 100 kHz |
Max Bandwidth | 6,6 kHz | 48 kHz | 28 kHz | 1 Hz | 1 Hz | 20 Hz | 20 Hz | 11 kHz | 14 Hz | 48 kHz | 11 kHz | 14 kHz | 14 kHz |
Voltage Mode | |||||||||||||
Isolated | |||||||||||||
Voltage up to 10 V | |||||||||||||
Voltage up to 50 V / 60 V | |||||||||||||
Isolation up to 800 V | |||||||||||||
Voltage up to 1000 V | |||||||||||||
Current | |||||||||||||
20 mA Internal Shunt | |||||||||||||
20 mA Shunt Plug | |||||||||||||
Temperature | |||||||||||||
Thermocouple (TC) | |||||||||||||
PT100 | |||||||||||||
Audio and Vibration | |||||||||||||
ICP Plug | |||||||||||||
Charge | |||||||||||||
Charge Mode Integrated | |||||||||||||
Charge Plug | |||||||||||||
Miscellaneous | |||||||||||||
Sensor Supply | |||||||||||||
Slots required | 2 | 1 | 4 | 2 | 3 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 |
Strain Gauge
UNI2-8 | UNI4 | DCB2-8 | DCBC2-8 | B-8 | BC-8 | BR2-4 | |
---|---|---|---|---|---|---|---|
Channels | 8 | 4 | 8 | 8 | 8 | 8 | 4 |
TEDS | |||||||
Speed per Channel | |||||||
Max Sampling Rate | 100 kHz | 100 kHz | 100 kHz | 100 kHz | 100 kHz | 100 kHz | 20 kHz |
Max Bandwidth | 48 kHz | 48 kHz | 5 kHz | 5 kHz | 48 kHz | 48 kHz | 8,6 kHz |
Voltage Mode | |||||||
Isolated | |||||||
Voltage up to 10 V | |||||||
Voltage up to 50 V / 60 V | |||||||
Current | |||||||
20 mA Internal Shunt | |||||||
20 mA Shunt Plug | |||||||
Temperature | |||||||
Thermocouple (TC) | |||||||
PT100 | |||||||
Bridge Mode | |||||||
Full Bridge | |||||||
Half Bridge | |||||||
Quarter Bridge | |||||||
DC Excitation | |||||||
AC Excitation (CF) | |||||||
Audio and Vibration | |||||||
IEPE Mode Integrated (ICP-, DeltaTron-, PiezoTron) | |||||||
ICP Plug | |||||||
Charge | |||||||
Charge Mode Integrated | |||||||
Charge Plug | |||||||
Miscellaneous | |||||||
Sensor Supply | |||||||
Sensor Supply/Channel | |||||||
Slots required | 2 | 1 | 2 | 1 | 2 | 1 | 1 |
Audio | Vibration
ICPU2-8 | ICPU-16 | AUDIO-4 | AUDIO-4-MIC | |
---|---|---|---|---|
Channels | 8 | 16 | 4 | 4 |
TEDS | ||||
Frecuencia de Muestreo por Canal | ||||
Max Frecuencia de Muestreo | 100 kHz | 20 kHz | 100 kHz | 100 kHz |
Max Ancho de banda (-3dB) | 48 kHz | 6,6 kHz | 48 kHz | 48 kHz |
Medida de Tensión | ||||
Aislado | ||||
Hasta 10 V | ||||
Hasta 50 V / 60 V | ||||
Audio y Vibración | ||||
Modo IEPE integrado (ICP-, DeltaTron-, PiezoTron) | ||||
Otros | ||||
Alimentación de sensores | ||||
Slots necesarios | 2 | 4 | 1 | 2 |
DI | DO | AO
Digital Inputs/Outputs, Analog Outputs, Control & Regulation Conditioners
DI16-DO8-ENC4 | DI8-DO8-ENC4-DAC4 | HRENC-4 | FRQ-4 | DI2-16 | DI-HV-4 (400V) | DO-16 | DO-16-HC | DAC-8 | SYNTH-8 | |
---|---|---|---|---|---|---|---|---|---|---|
Digital Inputs/Outputs | ||||||||||
Input Bits | 16 | 8 | 16 | 4 | ||||||
High Voltage | ||||||||||
Output Bits | 8 | 8 | 16 | 16 | ||||||
High Current | ||||||||||
Analog Outputs | ||||||||||
Analog Outputs | 4 | 8 | 8 | |||||||
Incremental Encoder | ||||||||||
Inputs | 4 | 4 | 4 | 4 | ||||||
Quadrature Mode | 2 | 2 | 4 | |||||||
Counter Frequency | 32 MHz | 32 MHz | 256 MHz | 256 MHz | ||||||
Analog sin/cos Mode | ||||||||||
Real-time Control & Regulation | ||||||||||
Signal Generator (Synthesizer) | ||||||||||
PID-Regulator | 8 | |||||||||
Conditioner Slots | ||||||||||
Slots required | 2 | 2 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Key: | Default | Optional |
About imc Test & Measurement
Productive testing is essential for the success of our customers—hence, our driving force. Since 1988 we have been committed to support industrial innovations with optimal measurement solutions. We are manufacturing our productive test and measurement systems at our headquarters in Berlin, Germany, operating worldwide in Europe, the US and Asia.
imc Test & Measurement is part of Axiometrix Solutions, a leading test solutions provider comprised of globally recognized measurement brands.
Contact us
imc Test & Measurement GmbH
Voltastraße 5
13355 Berlin (Germany)
Headquarters | info@imc-tm.de
France | hotline@imc-france.com
USA | accounts@imcdataworks.com
China | cnsales@imc-tm.com
Spain | info@imc-tm.es
South Korea | hotline@imc-tm.kr
Switzerland | info@imc-tm.ch
Netherlands | info@imc-benelux.com
© imc Test & Measurement GmbH. All rights reserved. Privacy. Incident Reporting. Company Information.